Alternative content

Get Adobe Flash player


KMA® 900

Multi Parameter Patient Monitor
../images/20091017170607.KMA900Katalog.pdf

KMA® 900 is a new generation patient monitor which is produced in latest technology, colored multi parameter, micro processor controlled (2-12 channel ECG, 1 SpO2, 1 respiration, invasive blood pressure, 1 non-invasive blood pressure, EtCO2, 2 temp. It has 12.1” color TFT-LCD display and 8 channels waveforms simultaneously. In addition, it has big numeric display mode. CO Cardiac Output, Anesthetic Gas Module (O2, N2O, CO2 and 5 anesthetic Agent) connections are available. The high and low alarm limits for the parameters being measured can be set easily. The device alarms with sound if the set alarm limits are exceeded. KMA®900 can display 120 hours trends of all parameters on screen in a zoom and parameterized way.

KMA®900 series monitors have several options. Up to 3 channel thermal printer, 1 channel cardiac output (CO), 1 extra channel  SpO2, up to 3 additional channels of invasive blood pressure, CO2 Module (EtCO2, inspired CO2&RR), 1 channel extra FiO2, Anesthetic Gas Module, 1 channel BIS (Bispectral Index), wireless connection to Central Station, Li-ion battery can be added for request. 


SAFETY
Safety IEC6060-1-1 approved, CE marking according to MDD 93/42/EEC
Degree of protection against harmful ingress of water IPX1
Environmental Requirements
Operating temperature 10 – 40 °C
Storage temperature -20 – 50 °C
Relative humidity 15 ~ 95 %
GENERAL
Dimensions TFT-LCD 12.1” (30.73 cm)
355(E) x 245(B) x 149(D)
Weight ~ 6 kg
Trace Line 8 kanal (Maks.)
Input and Output Connection VGA, Analog Output, Defib. sync. output, LAN Ethernet Network, 2 USB, RS232
Display Parameters Heart rate and alarm limits
SpO2, Pulse Rate and alarm limits
Blood Pressure (NIBP,IBP)
Respiration
Temperature
EtCO2
CO (Cardiac Output)
Trend of Heart Rate and other vital signs, value and time
Name, bed ID, date & time menu information
Event Table
Drug dose calculation
Thermal Printer 1-3 Channel Built-in thermal printer
POWER SUPPLY
Power Supply 100 - 240 VAC, 50 / 60 Hz, 100 VA
Battery Built-in rechargeable battery
ECG
Channels 12 (I,II,III,aVR,aVL,aVF,V1,V2,V3,V4,V5,V6)
ST measurement Level and slope of all leads
Arrhythmia Analysis Basic
Heart Rate Range (Max.) Adult – 300 bpm
Child/ Neonatal – 350 bpm
RESPIRATION
Measurement Range (Max.) 150 rpm
Apnea Alarm 5-40 sec.
Operating Modes Automatic / Manuel
SpO2
Measurement Range 0-100%
NIBP
Measurement Range (Max.) 300 mmHg
Patient Types Adult/child/neonate
Method Oscillometric pulse
Operation Modes Manuel
Periodic
STAT
Venous stasis
IBP
Measurement Range -50 ~ 450 mmHg
Accuracy ±2 mmHg
Transducer 5µV/V/mmHg
CO
Thermodilation 0.1-20 L/min.
  TB : 23- 43°C
TI : 0 – 27 °C
Accuracy ±5 % veya ±0.1 L/min
(whichever is greater)
TB, TI: ± 0.1 °C (without sensor)
TEMPERATURE
Measurement Range -5°C ~ 50 °C
Channels 2 Kanal; T1, T2 ve ?T
Accuracy ± 0.1 °C
Warning:
1- Our continuing product improvement program makes specifications subject to change without prior notice.
2- PETAS®, KARDIOPET®, KMA®, PETKOT®, MK®, PM® are registred trademark of PETAS® INC.


PETAŞ® Profesyonel Elektronik Sanayi ve Ticaret A.Ş. ©2010 All rights reserved. Terms of Use Contact Us